Microtek 700va Sebz (12 V) Inverter ( Microtek 700VA )

004

UPS SEBz 700 VA Battery : 1 Battery System Waveform : Pure SINEWAVE Input AC Range: Wide : 100V~300V AC,Standard:180V~260V AC Input DC Range :10.5~14.2 Efficiency (on batterymode):>80% Protections: Overload : 110%, Short - Circuit :300% Charger current all Models: Standard :10A ± 1A, High :14A ± 1A

More details

In stock

Check Your Location:

₹3,700

MRP : ₹5,690


Product Description

MICRO CONTROLLER/DSC BASED INTELLI PURE SINEWAVE UPS SEBZ is designed using latest state-of-the-art Technology for Better Performance and High Reliability. The INTELLIPURE SINEWAVE Technology used enhances the life of the battery and minimum effort has to be put for maintenance. Digital Signal Controller (DSC) Based Intelligent Control Design Pure Sine Wave Output PWM Controlled multistage ATM (Automatic Trickle Mode) Charging Display Indications (Status & Fault) Smart Overload Sense and Short Circuit Protection Easily Serviceable Auto Reset Feature Mains Input Voltage Range Selection Smart Boost function for Low Input Voltage: When the mains voltage is low, the smart boost will correct it back to its ormal ange without draining the battery. Smart Buck function for High Input Voltage: When the mains voltage is high, the AVR or smart buck will correct it back to its ormal ange without draining the battery. Over Voltage Protection: The UPS will switch to UPS mode & offers power from the battery when the mains voltage is too high. Over Load/Short Circuit Protection: If the UPS is excessively overloaded in UPS mode or encounters a short circuit, it will go into protection mode. The output will be shutdown in this case. Battery Deep Discharge/Over Charge Protection: The UPS has in-built electronic protection circuit which protects the batteries from getting deep discharged or over charged. Technical Specifications Input Voltage (Standard Range) (Narrow Range) : 100V~300V 180V~260V Output Voltage on Mains Mode : Same as Input Output Voltage on UPS Mode : 210V ± 10% Output frequency on UPS Mode : 50 Hz ± 0.1 Hz Switching from Mains to UPS and from UPS to Mains : Automatic Output Waveform on Mains Mode : Same as Input Output Waveform on UPS Mode : PURE SINE WAVE Battery Charging Current : Constant Charging Approx 10% of The Rated Battery Current in AH Charger : Power Factor Controlled Boost Technology Efficiency : > 80% UPS Overload / UPS Short Circuit : 110% / 300% UPS Transfer Time : ≤ 15 msec. Technology : Digital Signal Controller (DSC) Based Intelligent Control Design Auto Reset Feature : Yes NOTE : Because of a policy of continuous product improvement, the specifications are subject to change without otice.

Review

Login To Review..

Related Items